Previous
Next

20KVA Solar PV Input 450Vdc Pure Sine Wave Inverter DC 192V 380V 16KW Three Phase 380VAC Output Power MPPT

Reference: 16kw 3phase inverter
лв9,700.92
Tax included
Out-of-Stock

Pure sine wave output.

◇  Low DC voltage, saving system cost.

◆  Built-in PWM or MPPT charge controller.

◇  AC charge current 0-45A adjustable.

◆  Wide LCD screen, clearly and precisely shows icon data.

◇  100% imbalance loading design, 3 times peak power.

◆  Setting different working modes based on variable usage requirements.

◇ Various communication ports and Remote monitoring RS485/APP(WIFI/GPRS) (Optional)

Product Parameters

Specification

Model: NPHDSX

80248/96/192

10348/96/192

12348/96/192

163192/380

20396/192

24396/192

Rated Power

10KVA/8KW

12.5KVA/10KW

15KVA/12KW

20KVA/16KW

25KVA/20KW

30KVA/24KW

Peak Power(20ms)

24KVA

30KVA

36KVA

48KVA

60KVA

72KVA

Start Motor

5HP

6HP

7HP

10HP

10HP

15HP

Battery Voltage

48/96/192VDC

192V/380VDC

Size(L*W*Hmm)

725*365*1010

Packing Size(L*W*Hmm)

785*425*1135

N.W.(kg)

112

122

134

160

176

189

G.W.(kg)(Wooden Packing)

136

146

158

184

200

213

Installation Method

Tower

Parameter

Input

DC Input Voltage Range

10.5VDC-15VDC(Single battery voltage)

AC Input Voltage Range

380Vac/400Vac±10%(customized 190Vac/200Vac)

AC Input Frequency Range

45Hz-55Hz(50Hz)/ 55Hz-65Hz(60Hz)

Max AC charging current

0-45A(Depending on the model)

AC charging method

Three-stage (constant current, constant voltage, floating charge)

Phase

3/N/PE

Output

Efficiency(Battery Mode)

≥85%

Output Voltage(Battery Mode)

380Vac/400Vac±10%(customized 190Vac/200Vac)

Output Frequency(Battery Mode)

50/60Hz ±1%

Output Wave(Battery Mode)

Pure Sine Wave

Output waveform distortion

Linear load≤3%

Efficiency(AC Mode)

>99%

Output Voltage(AC Mode)

Conforming to AC input

Output Frequency(AC Mode)

Conforming to AC input

No load loss(Battery Mode)

≤2.5% rated power

No load loss(AC Mode)

≤2%rated power( charger does not work in AC mode)

No load loss(Energy saving Mode)

≤10W

Phase

3/N/PE

Battery Type

VRLA Battery

Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage)

Customize battery

Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel)

Protection

Battery undervoltage alarm

11V(Single battery voltage)

Battery undervoltage protection

10.5V(Single battery voltage)

Battery overvoltage alarm

15V(Single battery voltage)

Battery overvoltage protection

17V(Single battery voltage)

Battery overvoltage recovery voltage

14.5V(Single battery voltage)

Overload power protection

Automatic protection (battery mode), circuit breaker or insurance (AC mode)

Inverter output short circuit protection

Automatic protection (battery mode), circuit breaker or insurance (AC mode)

Temperature protection

>90°C(Shut down output)

Alarm

A

Normal working condition, buzzer has no alarm sound

B

Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection

C

When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal

Inside Solar controller
(Optional)

Charging Mode

MPPT or PWM

Charging current

PWM: 10A-60A(48V System); 50A/100A(96V System); 50A/100A(192V System)
MPPT: 10A-100A(48V System); 50A/100A(96V System)

PV Input Voltage Range

PWM: 60V-88V(48V System); 120V-176V(96V System); 240V-352V(192V System)
MPPT: MAX450V

Max PV Input Voltage(Voc)
(At the lowest temperature)

PWM: 100V(48V System); 200V(96V System); 400V(192V System)
MPPT: 150V(48 System); 300V(96V System); 450V(192V System)

PV Array Maximum Power

48V System: 560W(10A)/1120W(20A)/1680W(30A)/2240W(40A)/2800W(50A)/3360W(60A)/4480W(80A)/5600W(100A);
96V System: (PWM: 5.6KW(50A)/11.2KW(100A)) / (MPPT: 5.6KW(50A)/5.6KW*2(100A));
192V System: (PWM: 11.2KW(50A)/22.4KW(100A))

Standby loss

≤3W

Maximum conversion efficiency

>95%

Working Mode

Battery First/AC First/Saving Energy Mode

Transfer Time

≤4ms

Display

LCD

Thermal method

Forced air cooling

Communication(Optional)

RS485/APP(WIFI monitoring or GPRS monitoring)

Environment

Operating temperature

-10℃~40℃

Storage temperature

-15℃~60℃

Noise

2000m(More than derating)

Elevation

≤65dB

Humidity

0%~95% ,No condensation

16kw 3phase inverter
Comments (0)
No customer reviews for the moment.